Xinlong ImageTool Studio 0.3.2 - English Requirements: Windows 10/11 and .NET Framework 4.8. Extract to a writable folder, then run ImageToolStudio.exe. Dependencies are embedded; Python is not required. A vendor component may be extracted to the current user's local cache on first use. Compatibility: Use a barcode device supporting the applicable ImageTool image protocol. Confirm its model and firmware. A USB CDC interface alone does not establish compatibility. Quick start 1. Close other applications using the same COM port. Connect the device, select or auto-detect its port, and click Connect. 2. Communication defaults are 115200 baud, 8N1, no flow control, DTR/RTS off. Confirm the requirements of your device. 3. Read parameters and start image acquisition. Record baseline parameters and an image before adjusting exposure limits, gain, LED-current values and target brightness. 4. Live adjustments send temporary values. Save PNG/JPEG images, export XML parameters or scan-result text, and document test conditions. 5. PC decoding operates on the current image. Identify PC results separately from device output. An image acquired after a scan is not necessarily the exact frame used for successful device decoding. Device settings Editing, saving or importing a send plan, or generating a combined settings code, does not transmit or apply settings. Sent means the serial write completed, not that the device accepted the setting. Firmware querying was verified on the tested TTL / RS-232 sample; the earlier USB CDC sample did not return a firmware reply. Ordinary setting application and actual restart remain unverified. Confirm the control protocol before connection-changing or restart operations. Changes in 0.3.2 A Data codes category groups data digits 0-F and Save data parameters. DM connection setup codes remain fixed at the top of the image-parameter panel, with an enlarged view and a parameter-save code entry. USB CDC and TTL / RS-232 modes keep separate adapter and baud-rate preferences. Port detection or a firmware reply does not establish a working image channel. The tested TTL / RS-232 sample still returned no image parameters or complete image. Verified image acquisition remains limited to compatible USB CDC image-protocol devices. The company website link has been updated to www.xinlongiot.com. Files and records The program folder must be writable for connection preferences, images and local raw records. Only one program can open a COM port at a time. Results depend on barcode material, illumination, installation and firmware. Evaluate actual samples. Guide: https://xinlongiot.com/en/tools/image-tool-studio.html Technical support: lixuan@xinlongiot.com